
- #SIEMENS SIMATIC S7 300 MANUAL INSTALL#
- #SIEMENS SIMATIC S7 300 MANUAL UPDATE#
- #SIEMENS SIMATIC S7 300 MANUAL ARCHIVE#
The activity for each bit is predefined (for more details, see section SoftEvents). SoftEvents are a means of invoking an activity by manipulating a single control bit.
Select a destination folder to save the project on your PC. Select Dm200_SoftEvents.zip from the Siemens folder. When the reader sees the result acknowledge signal, clear result acknowledge, clear the read pending coil, and signal that the read process is complete. As soon as the results are available, save a copy of the result data and set the results acknowledge signal. As soon as the trigger signal is acknowledged, clear the trigger signal. Set the trigger signal and set coil to indicate a read is pending. In this example, a Data Block (DB) is defined containing the fields of the Result Data module that are relevant for our application. There are many options regarding how and where result data can be stored. Define an area in your application to save read results. Reduced to the basics, the process of reading and retrieving results consists of the following: #SIEMENS SIMATIC S7 300 MANUAL ARCHIVE#
The Siemens software extracts the sample archive and makes it available.Browse to find the sample file on your PC.
From the main menu, select File -> Retrieve…. #SIEMENS SIMATIC S7 300 MANUAL INSTALL#
Perform the following steps to install the program: Note: This sample can be used with any PROFINET enabled DataMan reader. If you choose to expand the process image area, make the size large enough for the module size plus the default 256 offset. As a solution, either remap the modules to lower offsets within the process image area or expand the process image area to include these modules.
That is, data in these modules are inaccessible by some SFCs such as BLKMOV. This is outside of the default process image area size of 128. By default, the SIMATIC software maps the User Data and Result Data Modules to offset 256.
#SIEMENS SIMATIC S7 300 MANUAL UPDATE#
In the IO Cycle tab, select the appropriate cyclic update rate for your application. As an alternative, if you wish the PLC to assign an IP address, select the Ethernet button and configure the appropriate address. If your DataMan reader is configured to use its own static IP, uncheck Assign IP address via IO controller. For details, see the SIMATIC Software help. The name must be unique and follow DNS naming conventions. This must match the name of your actual DataMan reader. Right-click the DataMan icon and select Object Properties…. You can change the module by deleting the one in the table and inserting the appropriate sized module from the catalog. To optimize performance, use the module size that most closely matches the actual data requirements of your application. There are multiple sizes available for both of these modules. Note: By default, the 64 byte User Data and 64 byte Result Data Modules are inserted.